Installing the Operating System 4-49
Installing and Configuring
System Software
This section contains supplemental information for installing and configuring SCO
UNIX® OpenServer® Release 5.0.X Operating System.
Installing SCO OpenServer Rel. 5.0.X Software
without a Disk Array Controller Installed
Note: This section assumes that you have properly completed
the hardware installation. If you have not done so, please refer to
the corresponding documentation and complete the hardware
installation before trying to proceed with driver installation.
Note: Read the Release Notes (packaged with your operating
system documentation) before starting the installation.
SCO installation instructions in the SCO UNIX OpenServer Rel. 5.0.6 Handbook
provide more extensive installation procedures. Chapter 2 of the SCO OpenServer
Rel. 5.0X Handbook Installation Guide includes an installation checklist to assist you
in installing or upgrading to SCO UNIX OpenServer 5.0.6.
1. Insert the SCO OpenServer Version 5.0.6 CD into the CD-ROM drive and boot
your system. You will see the following message:
SCO OpenServer™ Release 5.0.6
Boot:
Type: defbootstr link= ad160 Std=ad160 (0, 0, 0, 0)
Press ENTER.
2. The installation continues until the system displays this message:
Please insert the fd(65) ad160 volume and press <Return> or 'q' to quit.
3. Insert the Adaptec Ultra 160 Driver for SCO OpenServer 5.0.X diskette (made
from the EXPRESSBUILDER CD) into the floppy drive and press ENTER.
4. The system continues until the system displays this message:
Please enter “r’ if you wish to try replacement.
Type r and press ENTER.
5. The system displays standard SCO OpenServer Rel. 5.0.6 copyright messages
such as
Restricted Rights Legend. Use duplication, or disclosure.
Press ENTER to continue.
Press ENTER to accept.