PC Control Command Reference

Command Codes

No.

Function

Code

Data

Description

01

Video

03H

No

Same as remote

02

RGB1

04H

No

Same as remote

03

RGB2

05H

No

Same as remote

04

S-VIDEO

C6H

No

Same as remote

05

Power On

08H

No

Same as remote (See NOTE on page 37.)

06

Power Off

14H

No

Same as remote

07

Picture Mute

47H

No

Same as remote

08

Audio Mute

45H

No

 

09

Onscreen Mute

11H

No

 

10

Power Zoom W

09H

No

Same as remote

11

Power Zoom T

0AH

No

Same as remote

12

Power Focus +

0BH

No

Same as remote

13

Power Focus –

0CH

No

Same as remote

14

Reset

43H

No

(Resets immediately after returning ACK)

15

D Up

DEH

No

Same as remote

16

D Down

DFH

No

Same as remote

17

D Right

DCH

No

Same as remote

18

D Left

DDH

No

Same as remote

19

D Right Up

21H

No

Same as remote

20

D Left Up

22H

No

Same as remote

21

D Right Down

23H

No

Same as remote

22

D Left Down

24H

No

Same as remote

23

Freeze

4CH

No

Same as remote

24

Slide +

4BH

No

 

25

Slide -

20H

No

 

26

Front Floor

33H

No

 

27

Front Ceiling

34H

No

 

28

Rear Floor

35H

No

 

29

Rear Ceiling

36H

No

 

30

Auto Start On

19H

No

 

31

Auto Start Off

1AH

No

 

32

Auto Picture On

1BH

No

 

33

Auto Picture Off

1CH

No

 

34

Image mode Doc Cam

1DH

No

 

35

Image mode Normal

1EH

No

 

36

Image mode Natural

1FH

No

 

37

Power Management On

15H

No

 

38

Power Management Off

16H

No

 

39

Digital Zoom W

89H

No

Same as remote

40

Digital Zoom T

8AH

No

Same as remote

41

Brightness

60H

Yes

0 to 63

42

Contrast

62H

Yes

0 to 63

43

Color

64H

Yes

0 to 63

44

Tint

66H

Yes

-32 to +31(E0 to 1F)

45

Sharpness

68H

Yes

0 to 3

46

Audio Volume

6AH

Yes

0 to 63

47

Picture Adj

70H

Yes*

MT1020G: FFE0H to 001FH(–32 to +31) / MT820G: 768 to 1279 (2byte Code)

48

Fine Picture

6EH

Yes

MT1020G: 0 to 127 / MT820G: 0 to 31

49

H Position

72H

Yes

MT1020G: -128 to +127 (80 to 7F) / MT820G: -64 to +63 (C0 to 3F)

50

V Position

74H

Yes

MT1020G: -64 to +63(C0 to 3F) / MT820G: -32 to +31(E0 to 1F)

51

Lamp Reset

27H

No

 

52

Language Select

3DH

Yes

00: English, 01: German, 02: French, 03: Italian, 04: Spanish, 05: Swedish

*(Low-order data) (High-order data) CSUM

CSUM= Checksum is a low order digit of the sum from the Code to the immediately preceding data.

NOTE: These commands are subject to change without notice.

E – 36

Page 36
Image 36
NEC MT 1020G /820G user manual PC Control Command Reference Command Codes, Function Code Data Description