Diags Start Subcommand

Description: Starts the SP and platform-diagnostics framework. You must execute this command before running any tests. After running this command, you can immediately run Service Processor tests or wait for the subcommand diags get state to return the result platform diags available, at which point you can run platform tests.

The platform state must be either off or OS Communicating. Refer to the subcommand platform get os state for details about these states.

Format

Command format:

diags start {--noplatform}

Arguments

Description

 

 

{--noplatform}

Lets you enable diagnostics when the platform

 

power is on and the OS is running.

 

 

Return Codes

TABLE C-9lists the return codes for this subcommand.

TABLE C-9Return Codes for Subcommand diags start

Return Code

ID

Description

 

 

 

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage, conflicting

 

 

options specified.

NWSE_RPCTimeout

2

Request was issued, but was not serviced by the

 

 

server. RPC procedure timed out and the request may

 

 

or may not have been serviced by the server.

NWSE_RPCNotConnected

3

Unable to connect to the RPC server.

 

 

 

114 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004