Test Result (for example: Passed, Failed)

Details. If you specify the -voption, the Test Details are displayed, indicating detailed information about the test, such as high, low and nominal values, actual values, and so on. Upon failure, the Failure Details are displayed with a text message indicating the cause of failure.

Return Codes

TABLE C-8lists the return codes for this subcommand.

TABLE C-8Return Codes for Subcommand diags run tests

Return Code

ID

Description

 

 

 

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage, conflicting

 

 

options specified.

NWSE_RPCTimeout

2

Request was issued, but was not serviced by the

 

 

server. RPC procedure timed out and the request may

 

 

or may not have been serviced by the server.

NWSE_RPCNotConnected

3

Unable to connect to the RPC server.

NWSE_InvalidArgument

4

One or more arguments were incorrect or invalid.

NWSE_NoPermission

6

Not authorized to perform this operation.

NWSE_MissingArgument

7

Missing argument(s).

 

 

 