Diags Get Tests Subcommand

Description: Returns data describing the diagnostic tests that are available. This data includes the specific test name and the module to which the test applies.

Format

Command format:

diags get tests [{ -a --all}] [{-H --noheader}]] [{-D --delim <DELIMITER>}]

TABLE C-5lists the arguments for this subcommand.

TABLE C-5Arguments for Subcommand diags get tests

ArgumentsDescription

{-a --all}

{-H --noheader}

{-D --delim <DELIMITER>}

Specifies to return information for all tests in the server. Specifying no arguments also returns all tests available for each device in the server.

Suppresses header output.

Delimits columns with the specified delimiter. Headings are also delimited unless suppressed. The delimiter can be any character or string.

Return Codes

TABLE C-6lists the return codes for this subcommand.

TABLE C-6Return Codes for Subcommand diags get tests

Return Code

ID

Description

 

 

 

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage, conflicting

 

 

options specified.

NWSE_RPCTimeout

2

Request was issued, but was not serviced by the

 

 

server. RPC procedure timed out and the request may

 

 

or may not have been serviced by the server.

NWSE_RPCNotConnected

3

Unable to connect to the RPC server.

 

 

 

Appendix C Diagnostics Commands 111

Page 133
Image 133