Lights Out Management (LOM)

On these servers, Lights Out Management is performed through IPMItool, a utility for controlling IPMI-enabled devices.

Description

IPMItool is a simple command-line interface (CLI) to servers that support the Intelligent Platform Management Interface (IPMI) v1.5 specification. It provides the ability to:

Read the Sensor Data Record (SDR) and print sensor values

Display the contents of the System Event Log (SEL)

Print information about Field Replaceable Units (FRUs)

Read and set LAN configuration parameters

Perform chassis power control

Originally written to take advantage of IPMI-over-LAN interfaces, IPMItool is also capable of using a system interface, as provided by a kernel device driver such as OpenIPMI.

Further Information

For up-to-date information about IPMItool, visit: http://ipmitool.sourceforge.net/

For more information about the IPMI specification, visit: http://www.intel.com/design/servers/ipmi/spec.htm

For more information about the OpenIPMI project (MontaVista IPMI kernel driver), visit:

http://openipmi.sourceforge.net/

Syntax

The syntax used by IPMItool is as follows:

ipmitool [-ghcvV]-I lan -H address [-P password] expression

ipmitool [-ghcvV]-I open expression