SP Update Subcommands

The subcommands in TABLE H-91manage the SP flash.

TABLE H-91 SP Flash Subcommands

Subcommand

Description

 

 

sp update flash all

Sets the update flag to start the full flash update on the

 

next reset of the SP.

sp update flash applications

Copies the file Value-Addto the Value-Add

 

component of the SP flash.

sp update flash pic

Updates the PIC firmware to a newer version.

sp update diags

Updates the diagnostics to a newer version.

 

 

SP Update Flash All Subcommand

Note – Before using this command you must start the Java Update Server. For instructions on starting Java Update Server, see “Updating the Service Processor Base Component” on page 23.

Description: Updates the entire SP flash image (kernel, base file system and value add) as part of a major SP software update. This command requires the use of the Java Update Server and verifies that it is available before beginning the update process. Once verified, the SP is rebooted and the update process is initiated. When completed, the SP is automatically rebooted using the updated image.

Format

Command format:

sp update flash all {-i --ipaddress}

<IP ADDRESS xxx.xxx.xxx.xxx> [{-p --port}] <PORT#>

222 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Page 244
Image 244
Sun Microsystems V20Z SP Update Subcommands, SP Update Flash All Subcommand, Subcommands in Table H-91manage the SP flash