NEC R1000 manual Hardware Description and Specifications for Xen IPK Chapter, B64-U23 KSU

Models: R1000

1 110
Download 110 pages 18.54 Kb
Page 29
Image 29

Hardware Description and Specifications for Xen IPK Chapter 2

1.1B64-U23 KSU

1.1.1Basic KSU

The B64-U23 KSU provides service for outside lines, Attendant Consoles, and interconnection of the station terminals. The B64-U23 KSU has two fixed and eight flexible slots. The first fixed slot is reserved for the CPUI( )- U( ) ETU in the basic KSU or for the EXP-U( ) ETU in expansion KSUs. The second fixed slot is for the MIFA- U( ) ETU or MIFM-U( ) ETU.

The P64-U13 PSU (power supply unit), backup batteries, [one external MOH/BGM input, one external paging zone output] and three PFT relays are included with each KSU.

1.1.2Expansion KSUs

The B64-U23 KSU is also used as the expansion unit that can be attached to the basic KSU to provide additional ports. Two expansion units can be added to the Xen IPK system. Each expansion KSU provides eight flexible slots and accommodates 8-, 16-, 24-channel interface cards. The P64-U13 PSU (power supply unit), backup batteries, and three PFT relays are included with each KSU.

September 2003

Doc. No. 8283 - Release 1.0

Hardware Description and Specifications for Xen IPK

Chapter 2 – 21

Page 29
Image 29
NEC R1000 manual Hardware Description and Specifications for Xen IPK Chapter, B64-U23 KSU