NEC R1000 manual Terminal Type, Not applicable Data Assignment for ISDN-PRI Installation

Models: R1000

1 110
Download 110 pages 18.54 Kb
Page 73
Image 73

Xen IPK

SYSTEM

AVAILABILITY

OPERATING PROCEDURES

SERVICE

CONDITIONS

September 2003

Doc. No. 8283 - Release 1.0

Features and Specifications for Xen IPK

Terminal Type

All Stations.

Required Components

PRT(1)-U( ) ETU

CLKG-U( ) Unit

Not applicable.

Data Assignment for ISDN-PRI Installation

Use Memory Block 7-1 (Card Interface Slot Assignment) to select the PRT(1)-U( ) ETU.

Use Memory Block 1-8-33 (Master Clock Selection) to assign the source for necessary synchronisation of clocking.

Use Memory Block 1-13-00 (PRT Channel Assignment) to select the available B channels.

Use Memory Block 1-13-04 (PRT B Channel Outgoing Priority Selection) to specify how channels are selected for outgoing calls).

Use Memory Block 1-13-05 (PRT B-Channel-to-Trunk Group Assignment) to specify the correspondence between B channels and trunk groups.

Use Memory Block 1-1-80 (ISDN DTMF Duration/Interdigit Selection) to specify the tone duration (default: 100ms) and interdigit time (default: 70 ms) of DTMF signals sent from the ISDN trunk.

Use Memory Block 3-03 (Trunk-to-Trunk Group Assignment) to assign each ISDN-PRI trunk to a Trunk Group.

Use Memory Block 3-92 (Trunk Installed, DP/DTMF Selection) to specify each ISDN-PRI trunk as DP or DTMF.

Use Memory Block 3-91 (Trunk Type Selection) to specify each ISDN- PRI trunk as CO or DID. CO sets ISDN trunks for CO services. DID sets ISDN Trunks for DID services.

Use Memory Block 3-29 (Trunk Internal Transmit Pad Selection) to specify Internal Transmit volume level (default: 8 dB).

Use Memory Block 3-30 (Trunk Internal Receive Pad Selection) to specify Internal Receive volume level (default: 8 dB).

Use Memory Block 3-31 (Trunk External Transmit Pad Selection) to specify External Transmit volume level (default: 0 dB).

Use Memory Block 3-32 (Trunk External Receive Pad Selection) to specify External Receive volume level (default: 0 dB).

ISDN-PRI Trunk Connections I-8