(18/72)
5.5.2 Get Timing Report and Timing reply.
The controller requests the monitor to report the displayed image timing.
Send "07"(30h, 37h) as Get Timing Report command.
Complete "Get Timing Report" command packet as follows;
ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh
SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'7'-ETX-CHK- CR
The monitor replies status as the following format;
SS: Timing status byte
Bit 7 = 1: Sync Frequency is out of range.
Bit 6 = 1: Unstable count
Bit 5-2 Res erv ed ( Don 't car e)
Bit 1 1:Po sit ive Ho riz onta l s ync po lari ty.
0:Ne gat ive Ho riz onta l s ync po lari ty.
Bit 0 1:Po sit ive Ve rti cal syn c p ola rity .
0:Negative Vertical sync polarity.
H Freq: Horizontal Frequency in unit 0.01kHz
V Freq: Vertical Frequency in unit 0.01Hz
Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz.
Command code
STX '0' '7' ETX
Command SS H Freq. V Freq.
STX
'4'
'E'
Hi Lo MSB
LSB
MSB
LSB
ETX