***Following command also can be used for to keep backward compatibility, in order to write the setting of the Schedule.

1) The controller requests the monitor to write Schedule.

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'1'-'6'

STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MIN-

BCC

CR

OFF HOUR-OFF MIN-INPUT-WD-FL-ETX

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'1'-'6'(31h, 36h): Message length.

Message

STX (02h): Start of Message

'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command

PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data PG: Program No.

'0'-'0'(30h, 30h): Program No.1

'0'-'6'(30h, 36h): Program No.7

ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): ON timer isn't set.

ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59

'3'-'C'(33h, 43h): On timer isn’t set.

OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): Off timer isn't set.

OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0

'3'-'B'(33h, 42h): 59 (=3Bh)

'3'-'C'(33h, 43h): Off timer isn’t set.

INPUT: Timer input '0'-'0'(30h, 30h): DVI '0'-'1'(30h, 31h): VGA '0'-'2'(30h, 32h): RGB/HV '0'-'3'(30h, 33h): DVD/HD1 '0'-'4'(30h, 34h): VIDEO '0'-'5'(30h, 35h): S-VIDEO

'0'-'7'(30h, 37h): (Works on last memory)

*Please select active input on your system (setting).

*If you select inactive input here, the input change execution will be ignored.

WD: Week setting bit 0: Monday bit 1: Tuesday bit 2: Wednesday

(60/72)

Page 60
Image 60