10. Schedule read and write

10.1 Schedule Read

This command is used in order to read the setting of the Schedule.

1) The controller requests the monitor to read Schedule.

 

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'0'-'8'

STX-'C'-'2'-'2'-'1'-PG-ETX

BCC

CR

Header

 

 

 

SOH

(01h): Start Of Header

 

 

 

'0'

(30h): Reserved

 

 

 

Monitor ID: Specify the Monitor ID of which you want to get status. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'0'-'8'(30h, 38h): Message length

Message

STX (02h): Start of Message

'C'-'2'-'2'-'1' (43h, 32h, 32h, 31h): Schedule read request command.

PG: Program No.

The data must be ASCII characters strings. ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

2) The monitor replies Schedule to the controller.

Header

 

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-'2'-'6'

STX-'C'-'3'-'2'-'1'-PG-ON HOUR-ON MIN-

BCC

CR

 

 

OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-

 

 

 

 

EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX

 

 

Header

 

 

 

 

SOH (01h): Start of Header

 

 

'0' (30h): Reserved

 

 

 

'0' (30h): Message receiver is the controller.

 

 

Monitor ID: Indicate a replying Monitor ID.

 

 

Ex.)

When this byte is set to 'A', the replying Monitor ID is '1'.

 

'B' (42h): Message type is "Command reply".

 

 

'2'-'6'(32h, 36h): Message length

 

 

Message

 

 

 

 

STX (02h): Start of Message

 

 

'C'-'3'-'2'-'1'

(43h, 33h, 32h, 31h): Schedule read reply command

 

 

PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE- EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data

PG: Program No.

'0'-'0'(30h, 30h): Program No.1

'0'-'6'(30h, 36h): Program No.7

ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00

'1'-'7'(31h, 37h): 23 (=17h)

'1'-'8'(31h, 38h): ON timer isn't set.

ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0

(49/72)

Page 49
Image 49
NEC RS-232C manual Schedule read and write, Schedule Read