8. Asset Data read and write
MultiSync P402 /P462 /P552 /P702 /V422 /V462 /V551 /V651 /V322 /V652 /V552 /X461S /X551S /X401S /X463UN /X551UN /V463 /V423 have the area for to store user’s asset data of up to 64bytes.
8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header | Message | Check code | Delimiter |
BCC | CR |
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get data. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
Message
STX (02h): Start of Message
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area.
Maximum readout length is 32bytes at a time. ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
| Header | Message | Check code | Delimiter | |
| BCC | CR | |||
|
|
|
|
| |
| Header |
|
|
|
|
| SOH (01h): Start of Header |
|
|
| |
| '0' (30h): Reserved |
|
|
| |
| '0' (30h): Message receiver is the controller. |
|
| ||
| Monitor ID: Indicate a replying Monitor ID. |
|
| ||
| Ex.) | When this byte is set to 'A', the replying Monitor ID is '1'. |
| ||
| 'B' (42h): Message type is "Command reply" |
|
| ||
|
|
|
| ||
| Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h). | ||||
| Note.) This length includes STX and ETX. |
|
| ||
Message |
|
|
|
| |
| STX (02h): Start of Message |
|
|
| |
| (43h, 31h, 30h, 42h): Asset read reply command |
|
|
Data(0) – Data(N): Retuned Asset data
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
(40/72)