New Buck Corporation DV1000 Troubleshooting, Continued, Gas leak. See Warning statement, above

Models: DV1000

1 38
Download 38 pages 34.54 Kb
Page 32
Image 32
Continued

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

Burner system produces unwanted odors

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see

 

 

 

 

 

above

 

Checking Gas Connections, pages 15

 

 

 

 

 

 

 

thru 17

 

 

 

 

 

 

 

 

 

 

 

Burner system shuts off in use

1.

High or gusting winds

1.

Burner system has been tested for up

 

 

 

 

 

 

 

to 40 mph winds. However, extreme

 

 

 

 

 

 

 

conditions may occur. See Lighting

 

 

 

 

 

 

 

Instructions on page 21-22

 

 

 

 

2.

Low line pressure

2.

Contact local propane/LP or natural

 

 

 

 

 

 

 

gas company

 

 

 

 

3.

Pilot is partially clogged

3.

Clean pilot (see Cleaning and

 

 

 

 

 

 

 

Maintenance, page 25)

 

 

 

 

4.

Inner vent pipe leaking exhaust

4.

Locate and correct all leaks (see

 

 

 

 

 

gasses into system

 

Checking Gas Connections, pages 16

 

 

 

 

 

 

 

thru 17)

 

 

 

 

5.

Glass too loose and air tight gasket

5.

Tighten glass

 

 

 

 

 

leaks in corners after usage

6.

Replace faulty component

 

 

 

 

6.

Bad thermopile or thermocouple

 

 

 

 

7.

Improper vent cap installation

7.

Check for proper installation and

 

 

 

 

 

 

 

freedom from debris or blockage

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see

 

 

position

 

above

 

Checking Gas Connections, pages 16

 

 

 

 

 

 

 

thru 17)

 

 

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see

 

 

 

 

 

above

 

Checking Gas Connections, pages 16

 

 

 

 

 

 

 

thru 17)

 

 

Dark residue on logs or inside of burner

1.

Improper log placement

1.

Properly locate logs ( see Installing

 

 

system

 

 

 

Logs, page 19)

 

 

 

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets.

 

 

 

 

 

 

 

Periodically repeat as needed

 

 

 

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

 

Page 29

Page 32
Image 32
New Buck Corporation DV1000 manual Troubleshooting, Continued, Gas leak. See Warning statement, above, Instructions on page