OPERATING HEATER
Continued
OPTIONAL REMOTE
CONTROL
NOTE: All remote control accessories must be purchased separately (see Accessories). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the remote control unit. See Lighting Instructions on page 17.
OPERATING HEATER
Continued
PILOT FLAME PATTERN (MILLIVOLT)
Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not heating the thermo- couple. This will cause the thermo- couple to cool. When the thermo- couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 24:
•Turn heater off (see To turn Off Gas to Appliance, page 17)
•See Troubleshooting, pages 20 through 22.
THERMOPILE/
FIGURE 23 - CORRECT FLAME PATTERN L.P. OR NAT. GAS
THERMOPILE/
FIGURE 24 - INCORRECT PILOT FLAME PATTERN L.P. OR NAT. GAS
18