Nilfisk-ALTO 651BCL, 653BL, 661BL manuel dutilisation Fuse CHECK/REPLACEMENT

Models: 651BCL 653BL 653B 661BL

1 124
Download 124 pages 40.54 Kb
Page 90
Image 90

ENGLISH

USER MANUAL

 

 

 

 

FUSE CHECK/REPLACEMENT

1.Disconnect the battery connector (12).

2.Move aside the recovery water drain hose (16).

3.Remove the battery charger cable (I, Fig. 10), if equipped, from the cable holder (J).

4.Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel

(B).

5.Check/replace the following fuses:

(5a) Brush deck fuse F1: (40 A)

(5b) Vacuum system fuse F2: (30 A)

(5c) Drive system fuse F3: (30 A) (*)

(5d) Signal circuits fuse F4: (3 A)

(5e) Brush/pad-holder release fuse F5: (20 A)

(5f) Pump fuse F6: (3 A)

(*)Only for SCRUBTEC 653BL, SCRUBTEC 651BCL, SCRUBTEC 661BL

6.Perform steps 1 to 4 in the reverse order.

F G H A

A E

D

C

A J A

K

I

P100120

Figure 10

28

SCRUBTEC 653B – 653BL – 651BCL – 661BL

9097058000(2)2009-10 A

Page 90
Image 90
Nilfisk-ALTO 651BCL, 653BL, 661BL manuel dutilisation Fuse CHECK/REPLACEMENT