B:

If, on the other hand, a green spray lance is selected = 33 l/min + a standard spray lance = 17 l/min the maximum load on the line b-c= 33 l/min.

Use of 50 m 15 mm pipe will result in a pressure drop of:

Maximum load on line a-b= 50 l/min.

Use of 40 m 22 mm pipe will result in a pressure drop of:

Maximum load on line M-a= 50 l/min.

Use of 70 m 22 mm pipe will result in a pressure drop of:

Total pressure drop

PRESSURE DROP

9.3bar

2.0bar

3.2bar

14.5bar

The aggregate pressure drop on the three lines is less than 15 bar and the dimension require- ments have therefore been met.

Example 2

60 m

20

c

10m 20

c1

b1

 

a1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

b

 

 

 

 

 

a

 

 

 

 

 

 

 

 

 

 

30 m

 

 

 

 

30 m

 

10 m M

20

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

2

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

c

b

a

80 m

Branched system

Selection of spray lance: 2 green spray lances each of 33 l/min 2 blue spray lances each of 17 l/min

 

PRESSURE

Maximum load in each branch is 33 l/min

DROP

Use of15 mm pipe on e.g. the a-a2line

 

 

(20m) will result in a pressure drop of:

4.0

bar

Maximum load on line b-c= 66 l/min

 

 

Use of 30 m 22 mm pipe will result in a pressure drop of:

2.5

bar

Maximum load on line a-b + M-a= 101 l/min

 

 

Use of 40 m 22 mm pipe will result in a pressure drop of:

7.5

bar

Total pressure drop

14.0

bar

 

 

 

The aggregate pressure drop on the three lines is less than 15 bar and the dimension require- ments have therefore been met.

24

Page 24
Image 24
Nilfisk-ALTO 7309021 user manual Example 60 m, 30 m 10 m M 80 m, Pressure, Drop