3.10 Trouble-shooting and possible correction

Problem

Possible cause

Correction

 

 

 

 

 

 

 

 

 

 

 

System will not start or stops in

1) Mains power supply cut off

Connect mains power supply

 

mid-operation

 

 

 

(no indication of fault)

2) Fuses have blown

Check that fuses correspond to power con-

 

 

 

 

 

 

 

 

3) Control voltage fuses in DELTA

sumption (model plate). Renew fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOOSTER have blown

Call customer engineer

 

 

 

 

 

 

 

 

 

 

 

System does not start or stops in

Any of the below faults ia fatal and

When fault has been corrected restart

 

mid-operation with the following

should be corrected

system - check that the fault indication has

 

fault indication:

 

disappeared

 

 

 

 

 

 

 

 

 

 

C3K

 

 

 

 

 

Motor guard on motor 2 cut out:

*)  Call customer engineer

 

 

 

 

 

 

 

 

1) No phase

(C3K pump no. 2 can be withdrawn on the

 

 

 

 

 

 

 

 

2) Pump - motor blocked

steering - see section 3.5 - upon which the

 

 

 

 

 

 

 

 

3) Short-circuit in motor

operation can be resumed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C3K

 

 

 

 

 

Thermal cut-out sensor in motor 3 cut out

*)  Allow the motor to cool

 

 

 

 

 

 

 

 

1) Air intake obstructed

Check the air intake and clean, if necessary

 

 

 

 

 

 

 

 

2) Oil deficiency

Refill with oil.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water tank

 

 

 

Water level in water tank too low

Check that the shut-off’s on the water inlets

 

 

 

 

 

 

 

 

 

are open and clean the inlet filters, if ne-

 

 

 

 

 

 

 

 

 

cessary. Check that the water supply meets

 

 

 

 

 

 

 

 

 

the requirements stated in sect. 1.5

 

 

 

 

 

 

 

 

 

 

Water tank

Temperature in water tank too high

 

(>80°C)

 

Temperature in water tank too low (<2°C)

Allow the water to cool, empty the wa- tertank, if necessary. Check that the cold water connection is open and, if not, that the temp. on the hot connection does not exceed 75°C.

Empty the water tank, and make sure that the temperature of the water inlets are above 2°C.

Pipeline / internal hoses

Leakage: external or internal

In case of external leakage: disengage

 

 

 

 

 

 

 

any open spray handles, if relevant - repair

 

 

 

 

 

 

 

leakage.

 

 

 

 

 

 

 

In case of internal leakage: repair leakage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensors

 

 

 

 

Combination of sensor values illegal.

Call customer engineer

 

 

 

 

 

 

 

 

I.e. if the high pressure switch is ON and

 

 

 

 

 

 

 

the low pressure switch is OFF.

 

 

 

 

 

 

 

 

 

 

 

One or more pumps will not stop

High-pressure cock at outlet point does

Check that all high-pressure cocks at outlet

after end of operation

not close

points have been closed

 

 

 

 

 

 

Flow sensor return defective

Call customer engineer

 

 

 

Pump restarts at short intervals

The system cannot keep up pressure

Check that all high-pressure cocks at outlet

 

 

 

 

 

 

 

points have been closed

 

 

 

Working pressure too low

The high-pressure cock at outlet point

Check that all high-pressure cocks at outlet

 

 

 

 

 

 

not completely closed

points have been closed.

 

 

 

 

 

 

Double spray lance used at outlet point

Shift to single spray lance at this outlet

 

 

 

 

 

 

without injector

point.

 

 

 

 

 

 

Excessive water consumption

Check whether the water consumption of

 

 

 

 

 

 

 

the spray lances used exceeds the capacity

 

 

 

 

 

 

 

of the system - shift to other spray lances, if

 

 

 

 

 

 

 

necessary

No working pressure

High-pressure cock at one outlet point is

 

left open

Shut off the high-pressure cock at outlet points not in use

Irregular working pressure

Air in pump

Vent the system, cf. sect. 2.5.3

(machine vibrates)

Inlet water too hot

 

 

Allow water to cool and check that inlet

 

 

temperature does not exceed 80°C

 

 

 

Water volume at outlet point too

Blockage of filter for inlet water

Clean the filter, cf. sect. 3.9.2

small

Nozzle blocked

 

 

Clean the nozzle

*) In both cases the plant will stop and the related control lamp will flash. When restarting the plant, the pump will AUTOMATICALLY cut out, and the operation can be resumed - the control lamp will now be constantly alight.

If other faults occur than those enlisted, please contact your nearest Nilfisk-ALTO service centre.