56 Configuration

Nortel Networks Confidential

 

 

Table 10 Data Synchronization tab field descriptions

Field

Value

Description

 

 

 

maximumNumberofIdleContexts

Type=integer

This is the maximum

 

Range=1-10000

number of idle contexts at

 

numbers

any time. It should not

 

Default=100

exceed the maximum

 

 

number of contexts.

initialNumberofContexts

Type=integer

This is the initial number of

 

Range=1-10000

contexts to create. It

 

numbers

should not exceed the

 

Default=10

maximum number of

 

 

contexts.

maximumNumberOfContexts

Type=integer

This is the maximum

 

Range=1-10000

number of contexts to

 

numbers

create.

 

Default=1000

 

maximumExpires

Type=integer

This is the maximum

 

Range=60- 86400

allowable expiration value

 

seconds

for a DataSync

 

Default=3700

subscription request, in

 

 

seconds.

 

 

 

10Click on the Prov Sync Service tab. The Prov Sync Service parameter forwards provisioning modifications on user and device records to the SIP Application Module whenever modifications occur or when additions or deletions are made.

The Prov Sync Service tab allows the SIP Application Module to keep its configuration data updated with any changes that are made through the Provisioning Client web page. This tab also allows service providers to set how often the SIP Application Module queries the database for provisioning changes.