21Click on the SipFwdAdapter tab. This tab allows the service provider to set the valid events that the SIP Application Module will process and determines whether or not the SIP Application Server will or will not forward messages to a foreign server.

Figure 28 Completing the SipFwdAdapter tab fields

Table 21 SipFwdAdapter tab field descriptions (Sheet 1 of 2)

Field

Value

Description

 

 

 

maximumNumberOf

Type=integer

This is the maximum number

IdleContexts

Range=1-10000 numbers

of idle contexts at any time. It

 

Default=50

should not exceed the

 

 

maximum number of contexts.

initialNumberOf

Type=integer

This is the initial number of

Contexts

Range=1-10000 numbers

contexts to create. It should

 

Default=10

not exceed the maximum

 

 

number of contexts.

maximumNumberOf

Type=integer

This is the maximum number

Contexts

Range=1-10000 numbers

of contexts to create.

 

Default=5000

 

 

 

 