Figure 18 Completing the Overload Controls tab fields

Table 12 Overload Controls tab field descriptions (Sheet 1 of 2)

Field

Value

Description

 

 

 

Mem Polling Interval

Type=integer

This field indicates the number of

(sec)

Range=a positive

seconds to wait in between checks

 

integer

on memory usage.

 

Default=3

 

Minor Alarm

Type=integer

This field indicates the threshold at

Threshold (%)

Range=0-100 numbers

which Minor overload is

 

Default=80

encountered for both CPU and

 

 

memory.

 

 

 