46 EuroPak-15a Receiver User Manual Rev 5
Chapter 5 Commands
Syntax: Message ID: 229
Example:
AGCMODE L1 MANUAL 40 50
Table 17: Antispoofing Flag Values
AGCMODE FREQUENCY MODE [PULSEWIDTH LOADVALUE ]
Field Field
Name
Valid Values Description Format Binary
Bytes Binary
Offset
ASCII Binary
1header This field contains the Abbreviated ASCII command name. See Section 4.1
on Page 31.H 0
2frequency See Table15 on Page 45.Specif ies which signal
type to apply the
command to. Enum 4 H
3mode See Table16 on Page 45.
Specifies whether to
use the default or
custom values for the
pulse width and load
value.
Enum 4H+4
4pulsewidth 35 to 262144
Pulse width. A value is
only required when the
mode field is set to
MANUAL.
Float 4H+8
5loadvalue 35 to 262144
Modulus load value. A
value is only required
when the mode field is
set to MANUAL.
Float 4H+12
ASCII Description
FALSE Antispoofing is disabled.
TRUE Antispoofing is enabled.