Data Logs Chapter 6
EuroPak-15a Receiver User Manual Rev 5 79
Recommended Input:
LOG CLOCKMODELA ONTIME 1
Example Output:
#CLOCKMODELA,COM1,0,55.0,FINE,1048,497224.500,
00000128,879E,0;VALID,0,497224.500,497224.500,6.59596736E-01,-
9.29232987E-02,-3.40165918E+00,4.63006778E+02,1.19966616E+00,-
4.50054493E+02,1.19966616E+00,2.15673338E-01,-7.90256149E-01,-
4.50054493E+02,-7.90256149E-01,4.76057122E+02,-2.902,-1.03659974E-
01,FALSE*f33b4465
Table 36: Clock Model Status Values
Table 37: Constellation Change Flag Values
ASCII Binary Description
VALID 0The clock model is valid
CONVERGING 1The clock model is near validity
ITERATING 2The clock model is iterating towards validity
INVALID 3The clock model is not valid
ERROR 4Clock model error
ASCII Binary Description
FALSE 0There has not been a change in the constellation
TRUE 1The constellation has changed