Data Logs Chapter 6
EuroPak-15a Receiver User Manual Rev 5 93 Table 46: Receiver Status
Nibble # Bit # Mask Description Bit = 0 Bit = 1
N0
0 0x00000001 Error flag, see Table 45, Receiver
Error on Page 92 No error Error
1 0x00000002 Temperature status Within specifications Warning
2 0x00000004 Voltage supply status OK Warning
3 0x00000008 Antenna power status Powered Not powered
N1
4 0x00000010 LNA status OK Failure
5 0x00000020 Antenna open flag OK Open
6 0x00000040 Antenna shorted flag OK Shorted
7 0x00000080 CPU overload flag No overload Overload
N2
8 0x00000100 COM1 buffer overrun flag No overrun Overrun
9 0x00000200 Reserved
10 0x00000400 COM3 buffer overrun flag No overrun Overrun
11 0x00000800 Reserved
N3
12 0x00001000
13 0x00002000
14 0x00004000
15 0x00008000
N4
16 0x00010000
17 0x00020000
18 0x00040000 Almanac flag Valid Invalid
19 0x00080000 Position solution flag Valid Invalid
N5
20 0x00100000 Position fixed flag, see FIX on Page 56 Not fixed Fixed
21 0x00200000 Clock steering status Enabled Disabled
22 0x00400000 Clock model flag Valid Invalid
23 0x00800000 External oscillator flag PLL not locked PLL locked
N6
24 0x01000000 Stack warning OK Warning
25 0x02000000 Memory warning OK Warning
26 0x04000000 Message queue warning OK Warning
27 0x08000000 Message block usage warning OK Warning
N7
28 0x10000000 Reserved
29 0x20000000
30 0x40000000
31 0x80000000 AUX1 status event flag No event Event