Examples:
LOG COM1 PSRPOSA ONTIME 7 2.5 HOLD
LOG COM3 PRSPOSA ONCE
The first example configures the EuroPak-15a to output the PSRPOS log in ASCII format to COM1 at 7 second
intervals offset by 2.5 seconds (output at 2.5 seconds then 9.5 seconds and so on). The second example outputs
the log only once on COM3.
Table 27: Log Trigger Values
Table 28: Log Hold Values
ASCII Binary Description
ONNEW 0Output when the message is updated (not
necessarily changed).
ONCHANGED 1Output when the message is changed.
ONTIME 2Output on a time interval.
ONNEXT 3Output only the next message.
ONCE 4Output only the current message.
ASCII Binary Description
NOHOLD 0Allow log to be removed by the
UNLOGALL command.
HOLD 1Prevent log from being removed by the
UNLOGALL command.