66 EuroPak-15a Receiver User Manual Rev 5
Chapter 5 Commands
5.3.16 STHRESHOLD Control Signal ThresholdsThis command controls signal acquisition and steady-state-lock signal thresholds. The sigchan, acqui, lock and
crosscorr fields must have values. They set the thresholds for the specified L1 channel.
See also Table56 on Page 120 for the mapping of signal channels.
When you change this command, the selected channel loses lock and the locktime for its tracking satellite
is reset to zero.
Syntax: Message ID: 803
Example:
STHRESHOLD 0 35 20 35
STHRESHOLD SIGCHAN ACQUI LOCK CROSSCORR
Field Field
Name Valid Values Description Format Binary
Bytes Binary
Offset
1header This field contains the Abbreviated ASCII command name. See Section
4.1 on Page 31.H 0
2sigchan 0-15 The parameters should be applied
to this signal channel. Ulong 4 H+20
3acqui 25-80 Acquisition power threshold in
dBHz. ULong 4 H
4lock 10-80 Steady-state tracking lock
threshold in dBHz. ULong 4H+4
5crosscorr 10-80 Specifies the cross-correlation
power threshold in dBHz, at which
point, the checks are performed. ULong 4H+8