SPECIFICATIONS
CAN BE USED AS
•Watch
•Dive Computer (Air or Nitrox)
•Digital Depth Gauge/Timer
•Free Dive activity
NO DECOMPRESSION MODEL
Basis:
•Modified Haldanean Algorithm
•12 tissue compartments
Data Base:
•Diving Science and Technology (DSAT) - Rogers/Powell
Dive Computer Performance:
•Tissue compartment halftimes (mins.) Spencer’s “M” values 5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
•Reciprocal subsurface elimination
•60 minute surface credit control for compart- ments faster than 60 minutes
•Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities (stop ceilings):
•10, 20, 30, 40, 50, and 60 FT (3, 6, 9, 12, 15, and 18M)
Altitude Algorithm and Oxygen Exposure Limits:
•Based on NOAA tables
WATCH MODES
•Main Time (home)
>Set Time/Date
•Alternate Time (remote location)
>Set Alternate Time (hour differential)
•Countdown Timer
>Set/Start/Stop
•Chronograph (Stop Watch/Lap Timer)
>Start/Stop/Lap Recall/Reset
•Daily Alarm (Watch Mode)
>Set Time, On/Off
DIVE COMPUTER SURFACE SEQUENCE/MODES
•NORM/GAUG/FREE Surface Mode
•Plan (30 to 190 FT/9 to 57 M) - NORM only
•Time to Fly Countdown - NORM/GAUG
•Time to Desaturation Countdown - NORM only
•Dive Log - NORM/GAUG
•History - NORM/GAUG
•Oxygen Data (after Nitrox dives)
•Set FO2, Alarms, Utilities - NORM/GAUG
NORM/GAUG SET MODES |
|
• Set F Group (FO2 items): | Factory Settings: |
FO2 (Air, 21 to 50%) | Air |
FO2 Default (On/Off) | On |
• Set A Group (Alarms): |
|
Audible Alarm (On/Off) | On |
Depth (30 to 330 FT /10 to 100 M) | 330 FT |
EDT (:10 to 3:00 hr:min) | 3:00 (hr) |
TLBG (1 to 5 segments) | 5 (Deco) |
DTR (:00 to :20 min) | :20 (min) |
PO2 (1.20 to 1.60 ATA) | 1.60 ATA |
131