SPECIFICATIONS

CAN BE USED AS

Watch

Dive Computer (Air or Nitrox)

Digital Depth Gauge/Timer

Free Dive activity

NO DECOMPRESSION MODEL

Basis:

Modified Haldanean Algorithm

12 tissue compartments

Data Base:

Diving Science and Technology (DSAT) - Rogers/Powell

Dive Computer Performance:

Tissue compartment halftimes (mins.) Spencer’s “M” values 5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480

Reciprocal subsurface elimination

60 minute surface credit control for compart- ments faster than 60 minutes

Tissue compartments tracked up to 24 hours after last dive

Decompression Capabilities (stop ceilings):

10, 20, 30, 40, 50, and 60 FT (3, 6, 9, 12, 15, and 18M)

Altitude Algorithm and Oxygen Exposure Limits:

Based on NOAA tables

WATCH MODES

Main Time (home)

>Set Time/Date

Alternate Time (remote location)

>Set Alternate Time (hour differential)

Countdown Timer

>Set/Start/Stop

Chronograph (Stop Watch/Lap Timer)

>Start/Stop/Lap Recall/Reset

Daily Alarm (Watch Mode)

>Set Time, On/Off

DIVE COMPUTER SURFACE SEQUENCE/MODES

NORM/GAUG/FREE Surface Mode

Plan (30 to 190 FT/9 to 57 M) - NORM only

Time to Fly Countdown - NORM/GAUG

Time to Desaturation Countdown - NORM only

Dive Log - NORM/GAUG

History - NORM/GAUG

Oxygen Data (after Nitrox dives)

Set FO2, Alarms, Utilities - NORM/GAUG

NORM/GAUG SET MODES

 

Set F Group (FO2 items):

Factory Settings:

FO2 (Air, 21 to 50%)

Air

FO2 Default (On/Off)

On

Set A Group (Alarms):

 

Audible Alarm (On/Off)

On

Depth (30 to 330 FT /10 to 100 M)

330 FT

EDT (:10 to 3:00 hr:min)

3:00 (hr)

TLBG (1 to 5 segments)

5 (Deco)

DTR (:00 to :20 min)

:20 (min)

PO2 (1.20 to 1.60 ATA)

1.60 ATA

131