NORM DIVE NO DECO SAFETY STOP

Upon ascending to 5 FT (1.5 M) below the Safety Stop Depth set on any No Decompression dive in which Depth exceeded 30 FT (9 M), a short beep will be emitted and a Safety Stop at the Depth set will appear on the display with a countdown timer that begins at the Safety Stop Time set.

The Safety Stop will be displayed until the countdown times out (0:00 min:sec), or you descend below 30 FT (10 M), or you breach the surface. There is no Penalty if you surface prior to completing the Safety Stop.

If the Safety Stop was set to OFF, the screen will not appear during the ascent.

NO DECO SAFETY STOP MAIN DISPLAY, information in-

cludes (Fig. 73)

>TLBG representing Nitrogen loading.

>Graphics SAFE, STOP, and xxF (or xxM), scrolling, indicating the Stop Depth set.

>Current Depth with FT (or M) icon.

>Dive Time Remaining (hr:min) with TIME and NDC (or O2) icons.

>Safety Stop Countdown Time set/remaining (min:sec) with STOP and TIME icons.

>Nx icon, if FO2 is set for Nitrox.

• Press/release the A button to view the ALT 1 Display.

Fig. 73 - NO DECO

SAFETY STOP MAIN

81