Upon ascending above 330 FT (100 M), the Current Depth display will be restored, however Max Depth will only display 3 dashes for the remainder of that dive. Also, the Log for that dive will display 3 dashes as the Max Depth achieved.

IMMEDIATE VIOLATION AND VIOLA GAUGE MODE

If a Decompression Ceiling Stop Depth much greater than 60 FT (18 M) is required, an Immediate Violation Mode will be entered. This situation would be preceded by entering Delayed Violation Mode #2.

The GEO would then operate in Violation Gauge Mode during the remainder of that dive and for 24 hours after surfacing.

Violation Gauge Mode turns the GEO into a digital instrument without any decompression or oxygen monitoring functions.

VIOLATION GAUGE DIVE MAIN DISPLAY (Default),

information provided includes (Fig. 86) - > Full TLBG and UP Arrow, flashing. > Message UP > VIOL, scrolling.

> Current Depth with FT (or M) icon.

> Dive Time Remaining as 0:00 (hr:min) with TIME and NDC icons.

> Elapsed Dive Time (hr:min) with DIVE and TIME icons. > Nx icon, if FO2 is set for Nitrox.

Fig. 86 - VIOLATION

GAUGE MAIN

89