Fig. 47 - SET WET

ACTIVATION

Fig. 48 - SET UNITS

SET WET ACTIVATION, information includes (Fig. 48):

>Graphic WET

>Set Point graphic ON (or OFF) flashing.

Pressing and releasing the S button will toggle between ON and OFF.

Pressing and releasing the A button momentarily (< 2 seconds) will save the setting and/or advance to the SET UNITS screen with the Set Point flashing.

Pressing and releasing the A button momentarily and repeatedly (< 2 seconds each time) will step through the other SET U screens.

Depressing the A and S buttons simultaneously for 2 seconds will save the setting and revert back to the SET U screen.

Depressing and holding the M button for 2 seconds or if no button is pressed for a period of 2 minutes operation will revert to the NORM or GAUG SURF MAIN screen.

SET UNITS, information includes (Fig. 48):

>Graphic UNIT

>Set Point, FT icon and F graphic (or M icon and C graphic) flashing, with degrees icon.

Pressing and releasing the S button will toggle between Imperial (FT, F) and Metric (M, C).

54