Pressing and releasing the A button momentarily (< 2 seconds) will save the Safety Stop settings and/or advance to the SET CONS screen with the Set Point flashing.

Pressing the A button momentarily and repeatedly (< 2 seconds) will step through the other SET U screens.

Depressing the A and S buttons simultaneously for 2 seconds will save the settings and revert back to the SET U screen.

Depressing and holding the M button for 2 seconds or if no button is pressed for a period of 2 minutes operation will revert to the NORM or GAUG SURF MAIN screen.

SET NORM/FREE CONSERVATIVE FACTOR, information includes (Fig. 50):

>Graphic CONS

>TIME and NDC icons.

>Set Point ON (or OFF) flashing.

Pressing and releasing the S button (< 2 seconds) will toggle between ON and OFF.

Pressing and releasing the A button momentarily (< 2

seconds) will save the setting and/or advance to the SET BACKLIGHT DURATION screen with the Set Point flashing.

• Pressing and releasing the A button momentarily and repeatedly (< 2 seconds each time) will step through the other SET U screens.

• Depressing the A and S buttons simultaneously for 2 seconds will save the setting and revert back to the SET U

Fig. 50 - SET

screen.

CONSERVATIVE

 

56