No off gassing Credit will be given while above a Required Stop Depth, and for each minute above it 11/2 minutes of Penalty Time will be added to Required Stop Time and TAT (Total Ascent Time).

The added Penalty (decompression) Time will have to be worked off first, before obtaining off gassing credit will be given.

Once the Penalty Time is worked off, and off gassing Credit begins, required Deco Stop Depths and Time will decrease toward zero. The TLBG will recede into the No Deco Zone and the GEO will revert to the No Deco Dive Mode.

NOTE: Upon entry into the following Delayed Violation Modes, the Audible Alarm will sound and the red LED will flash even if Set OFF.

When these events occur, the Alarm cannot be acknowledged/silenced by pressing the S button.

DELAYED VIOLATION #1 (Fig. 83)

If you remain above the Required DECO Stop Depth for more than 5 minutes, the full TLBG and DOWN Arrow will flash until you descend below the Required Stop Depth. Also, the graphic message DOWN > TO > xxF (or xxM) will continue to

scroll. This is a continuation of a Conditional Violation.

Fig. 83 - DELAYED

 

VIOLATION #1 MAIN