7 Start the recording.

When the sound volume is lower than the preset threshold sound level, recording automatically stops after 1 second approximately, and “STANDBY” flashes on the display. The record/play indicator lamp glows when recording starts and flashes when recording pauses.

0 0 M 5 1 S

S T A N D B Y

Low

High

Adjust the start/stop actuation level

Using the VOLUME control, adjust the start/stop actuation level.

The VCVA level can be set to any of 15 different values. The higher the value, the more sensitive the recorder to sounds. At the highest value, even the faintest sound will activate recording.

The VCVA pause sound level can be adjusted according to the ambient (background) noise.

aStart level

0 0 M 5 8 S VCVA LEVEL

a0 6

Using the

Variable Control

Voice

Actuator

.........................................................................................................

Notes

The start/stop actuation level also varies depending on the selected microphone sensitivity mode (P.19).

To ensure successful recordings, prior testing and adjustment of the start/stop actuation level is recommended.

(VCVA)