MENU SELECTIONS

PRIMARY MENU

Press INDEX to advance to the next menu item. Press UP ARROW or DOWN ARROW to change the value in the display. Press ENTER to retain the value.

SP1 Set Point 1 Adjust, Control Point 1.

SP2 Set Point 2 Adjust, Control Point 2.

SECONDARY MENU

Hold UP ARROW & ENTER. Press INDEX to advance to the next menu item. Press UP ARROW or DOWN ARROW to change the value in the display. Press ENTER to retain the value.

Edit Edit Set Point parameters: Select 0, 1, 2, or 3.

0Edit function is off.

1Edit Secondary and Secure Menus for Set Point 1.

2Edit Secondary and Secure Menus for Set Point 2.

3 Edit Secondary and Secure Menus for both Set Points in sequence (menu items for Set Point 1

followed by menu items for Set Point 2).

If Edit is set to 0, begin.

If Edit is set to 1 or 3, jump to Out1 on page 17. If Edit is set to 2, jump to Out2 on page 21.

PEA1 The Peak feature stores the highest input the control has measured for Zone 1 since the last reset or Power On. At Power On, PEA1 is reset to the present input value. To manually reset the value PEA1 must be in the lower display. Press the ENTER key to reset. PEA1 will be reset and display the present input value.

UAL1 The Valley feature stores the lowest input the Instrument has measured for Zone 1 since the last reset or Power On. At Power On, UAL1 is reset to the present input. To manually reset the value UAL1 must be in the lower display. Press the ENTER key. UAL1 will be reset and display the present input value.

PEA2 The Peak feature stores the highest input the control has measured for Zone 2 since the last reset or Power On. At

Page 15 of 40

Page 17
Image 17
Omega Engineering CN 79000 manual Menu Selections Primary Menu, Secondary Menu