GENERAL SPECIFICATION

GENERAL SPECIFICATION

TEMPERATURE DATALOGGER

SPECIFICATIONS

OM8800D

 

 

 

 

OM88128

TEMP. RANGE

 

 

o

 

 

 

 

-40~85 C

 

 

 

 

 

-40~185oF

 

 

 

SHAPE

OVAL

 

 

 

SQUARE

 

 

 

 

 

 

 

OM88128

 

 

 

 

 

 

POWER BAT.

ER3 or CR2 lithium battery x1

 

ACCURACY

Temp.+

0.6oC(-20~50oC)

o

 

-

o

o

 

 

+

 

 

 

 

 

 

 

-1.2 C(-40~20 C,51~85 C)

 

SAMPLE DATA

Up to 8000

 

 

 

 

up to 16000

SAMPLE POINTS

1K/2K/4K/8K

 

 

1K/2K/4K/8K/12K/16K

HOUSING

 

WATERPROOF

 

DIMENSIONS(mm)

124(L)x92(W)x37(T)(Interface)

 

108(L)x66(W)x22(T)

 

 

80(L)x55(W)x22(T)

 

124(L)x92(W)(Complete set)

 

LED SIGNAL

Red (HI,LO Alarm) /Yellow(Record)

RESOLUTION

0.1oC (0.1oF) for range -40oC~50oC

 

0.1o C (0.1oF)

 

0.2oC for range 50~70oC

 

 

 

 

 

 

0.3oC for range 70~85oC

 

 

 

 

 

CABLE LENGTH

150 cm with DB9 connector

 