2.3 Program Control Commands

2.3.1 List of Program Control Commands

Command Type

Command

Function

 

 

 

 

UD

Returns the screen to the standard screen.

 

AK

Acknowledges the alarm(s).

 

MI

Initializes the data memory.

 

EV

Writes a time-axis mark or raises a manual trigger.

 

BO

Specifies the bit sequence in bytes (for binary output).

Control

TS

Specifies which data value is to be output.

 

FM

Specifies the data format of the measured value to be output.

 

LF

Specifies the channel for the request for the set value (TS1 command) or the

 

 

unit and decimal point (TS2 command).

 

LO

Loads the specified SET configuration file.

 

LI

Saves the settings (made in SET mode) with the specified file name.

 

ME

Write the messages.

 

UM

Switch the display

2.3.2 Standard Screen Call

(For the standard screen, see Section 1.6.1 of the instruction manual for the VR100 or the VR200.)

Command

Function

UD0

Returns the screen to the standard screen.

UD1

Returns the digital values for channels 1 to 3.

UD2

Returns the digital values for channels 4 to 6.

UD3

Returns the digital values for channels 1 to 6.

2.3.3 Alarm Acknowledge

(See Section 3.3 of the instruction manual for the VR100 or the VR200.)

Command

Function

AK0

Starts the alarm acknowledge function.

2.3.4 Initializing the Data Memory

(See Section 5.3 of the instruction manual for the VR100 or the VR200.)

Command

Function

MIYES

Initializes the data memory.

2.3.5 Writing a Time-axis Mark and Raising an Event Trigger

(See Sections 3.5 and 3.7 of the instruction manual for the VR100 or the VR200.)

Command

Function

EV0

VR100 and VR200 with style number 1 or lower: Writes a time-

 

axis mark.

 

VR200 with style number 2 or higher: Writes a message 1.

EV1

Raises a manual trigger.

 

The manual trigger is effective only when the sample mode is set

 

to trigger-on or trigger-rotation and the key trigger is set to ON.

2.3.6 Designating the Sequence of Byte Output (for Binary Output)

Command

Function

BO0

Designates that the measured values are to be output from the most

 

significant byte (see Page 3-4).

BO1

Designates that the measured values are to be output from the least

 

significant byte (see Page 3-4).

2 - 10