3.2 Output Data Formats

3.2.2 Output Format of Measured Values in Binary Mode

When the TS0, ESC T and FM1 commands are received, the measured values and computed results are output in binary.

Output format:

(1) Sequence of transfer

Byte

1 2 3 4 5 6

Number of bytes sent (2 bytes)

Date and time (6 bytes)

Measured data 1 (5 bytes)

Measured data n (last) (5 bytes)

(2) Number of bytes sent

Number of bytes sent = 5 n + 6

This parameter can be sent either from the most significant byte or from the least significant byte, as specified by the BO command.

Note that the 2 bytes of the “number of bytes sent” itself are not included.

(3) Date and time

Byte

1

2

 

3

4

5

6

 

 

 

 

 

 

 

Year

 

Month

Day

Hour

Minute

Second

 

 

 

 

 

 

 

 

Year :

0 to 99

(00H to 63H)

 

 

 

Month :

1 to 12

(01H to 0CH)

 

 

 

Day :

1 to 31

(01H to 1FH)

 

 

 

Hour :

0 to 23

(00H to 17H)

 

 

 

Minute :

0 to 59

(00H to 3BH)

 

 

 

Second : 0 to 59

(00H to 3BH)

 

 

 