r 1 =Input | Type | and | Range | Value |
|
| r2 = Decimal Point Position | |||
0 | = | TC | J | From | to | 1000 | °C | (Available only for linear range r1 = 15 to 22) | ||
1 | = | TC | K | From | to | 1370 | °C | _ _ _ _ . | = No decimal | |
2 | = | TC | T | From | to | 400 | °C | _ _ _ . _ | = One decimal figure | |
3 | = | TC | E | From | to | 800 | °C | _ _ . _ _ | = Two decimal figures | |
4 | = | TC | N | From | to | 1400 | °C | _ . _ _ _ | = Three decimal figures | |
5 | = | TC | S | From | to | 1760 | °C |
|
| |
6 | = | TC | R | From | to | 1760 | °C |
|
| |
7 | = | TC | B | From | 0 | to | 1820 | °C | r3 = Initial value of the readout scale | |
8 | = | TC | L | From | to | 900 | °C | (Available only for linear range r1 = 15 to 22) | ||
9 | = | TC | U | From | to | 600 | °C | Range: From | ||
10 | = | TC | G | From | 0 | to | 2300 | °C |
|
|
11 | = | TC | D | From | 0 | to | 2300 | °C |
|
|
12 | = | TC | C | From | 0 | to | 2300 | °C | r4 = final value of the readout scale | |
13 | = | TC Plat. II | From | to | 1400 | °C | (Available only for linear range r1 = 15 to 22) | |||
14 | = | RTD Pt 100 | From | to | 850 | °C | Range: From | |||
15 | = | Linear | From | 0 | to | 60 | mV |
|
| |
16 | = | Linear | From | 12 | to | 60 | mV |
|
| |
17 | = | Linear | From | 0 | to | 20 | mA | r5 = Offset Adjustment | ||
18 | = | Linear | From | 4 | to | 20 | mA | Range: From | ||
19 | = | Linear | From | 0 | to | 5 | V | Offset value algebraically added to the measured | ||
20 | = | Linear | From | 1 | to | 5 | V | value. |
| |
21 | = | Linear | From | 0 | to | 10 | V |
|
| |
22 | = | Linear | From | 2 | to | 10 | V |
|
| |
23 | = | TC | J | From | to | 1830 | °F | r6 =Time constant of the filter applied to | ||
24 | = | TC | K | From | to | 2500 | °F | the displayed | value | |
25 | = | TC | T | From | to | 750 | °F | Range: From 0 (filter OFF) to 8 seconds. | ||
26 | = | TC | E | From | to | 1470 | °F | (First order filter with selected time constant.) | ||
27 | = | TC | N | From | to | 2550 | °F |
|
| |
28 | = | TC | S | From | to | 3200 | °F |
|
| |
29 | = | TC | R | From | to | 3200 | °F | r7 = Alarm action on input fault. | ||
30 | = | TC | B | From | 32 | to | 3300 | °F | When the instrument detects an input failure | |
31 | = | TC | L | From | to | 1650 | °F | condition, the alarm will operate as in presence of: | ||
32 | = | TC | U | From | to | 1110 | °F | uP = as in presence of the full scale value. | ||
33 | = | TC | G | From | 0 | to | 4170 | °F | doun = as in presence of the initial scale value. | |
34 | = | TC | D | From | 0 | to | 4170 | °F |
|
|
35 | = | TC | C | From | 0 | to | 4170 | °F |
|
|
36 | = | TC Plat. II | From | to | 2550 | °F | C1 = Type of limit | action | ||
37 | = | RTD Pt100 | From |
| to | 1560 | °F |
|
| |
|
|
|
|
|
|
|
|
| 10 |
|
10 | 19/04/2004, 15.07 |