NOTE:

1)For band alarm, H.A./H.A.Ac/H.L. signifies outside band alarm, while L.A./ L.A.Ac/L.L. signifies inside band alarm.

2)The "Silence" function allows the manual reset of the alarm even if the alarm condition is still in progress.

Example for P2 = H.A.

 

(Alarm

(Alarm

threshold)

Hysteresis)

 

Alarm status*

Relay

Non alarm status

ON

ALM LED FLASHFLASH

OFF

Manual reset

*Alarm Status: Relay energized (P3 = dir) Relay de-energized (P3 =rEV)

Example for P2 = H.A.A.c

(Alarm

(Alarm threshold) Hysteresis)

Alarm status*

Relay

Non alarm status

ON

ALM LED FLASHFLASH

OFF

Manual reset

*Alarm Status: Relay energized (P3 = dir) Relay de-energized (P3 =rEV)

Example for P2 = H.L.

(Alarm

(Alarm threshold) Hysteresis)

Alarm status*

Relay

Non alarm status

ON

ALM LED

 

 

 

 

FLASH

FLASH

OFF

Manual

Manual

 

 

reset

reset

*Alarm Status: Relay energized (P3 = dir) Relay de-energized (P3 =rEV)

P3 = Alarm Action

(Skipped if option not is available or P1 = none) dir = Direct action

(Relay energized in alarm condition) rEV = Reverse action