GENERAL SPECIFICATIONS
Case: Polycarbonate grey case
Self extinguishing degree:
(*)Test were performed in accordance with IEC 529, CEI
Rear terminal board: 15 screw terminals (screw M3, for cables from φ 0.25 to φ 2.5 mm2 or from AWG 22 to AWG 14 ), connection diagram and safety rear cover.
Dimensions: 48 x 48 mm (according to DIN 43700); depth
- 122 mm for models with
- 105 mm for models without
Power supply : (switching mode) from 100 to 240 V AC. 50/60 Hz (+10 % to
24 V DC/AC (+10 % of the nominal value).
Power consumption: 8 VA.
Insulation resistance: > 100 MΩ according to IEC
Isolation voltage: 1500 V r.m.s. according to IEC
Common mode rejection ratio:
120 dB @ 50/60 Hz.
Normal mode rejection ratio: 60 dB @ 50/60 Hz.
Electromagnetic compatibility and safety requirements: This instrument is marked CE. Therefore, it is conforming to council directives 89/336/EEC (reference harmonized standard EN
Installation category: II
D/A conversion: dual slope integration. Sampling time :
-for linear inputs = 250 ms.
-for TC or RTD inputs = 500 ms. Display updating time: 500 ms. Resolution: 30000 counts.
Temperature Drift (CJ excluded)
-Less than 200 ppm/°C of full span for mV and TC ranges 0, 1, 3, 4, 8, 13, 23, 24, 26, 27, 31, 36 (CJ excluded).
-Less than 300 ppm/°C of full span for mA, V and TC ranges 10, 11, 12, 33, 34, 35 (CJ excluded)
-Less than 400 ppm/°C of full span for RTD and TC range 9, 32 (CJ excluded).
-Less than 500 ppm/°C of full span for TC ranges 2, 5, 6, 25, 28, 29 (CJ excluded).
-Less than 600 ppm/°C of full span for TC ranges 7, 30.
NOTE: Precision and drift guaranteed (for T>300°C/570°F).
Accuracy: + 0.2% f.s.v. @ 25 °C (77 °F) and nominal power supply voltage.
Operative temperature: from 0 to +50 °C (32 to 122 °F).
Storage temperature: from
Humidity: from 20% to 85 % RH not condensing.
21
21 | 19/04/2004, 15.07 |