Recording
Useful functions
DISP/MODE CHK
ZEBRA
A DISP/MODE CHK button B ZEBRA button
C QUICK START button D BARS button
BARS | QUICK START | ||
|
|
|
|
Quick Start
1 Press and hold down the QUICK START button until the display on the LCD monitor/ viewfinder disappears.
The quick start lamp E flashes green and the unit goes into
Quick Start Standby Mode.
2 Press the QUICK START button.
The quick start lamp E goes off and the unit is put into recording pause about 0.6 seconds.
≥When in Quick Start Standby Mode about 80% of the power used in recording pause mode is being consumed, so the recording time will be reduced.
≥This unit is turned off after approximately 30 minutes elapse in Quick Start Standby Mode.
≥Quick Start Standby Mode is cleared when the mode switch is set to .
≥Depending on the recording conditions and menu settings, time for Quick Start may be longer than 0.6 seconds.
≥It may take some time for Automatic White Balance to adjust.
≥In the Quick Start Mode, the zoom magnification becomes approximately 1k.
-61 -