ERROR MESSAGES

When trouble has occurred in the VTR, one of the following messages appears on the tape counter.

The VTR stops operating when any of the error numbers except E-00 and E-01 is displayed.

Error No.

d —

E

00

E

01

E

11

E

21

E

31

E

32

E

41

E

42

E

43

E

44

E

51

E

52

E

53

E

61

E

62

E

63

E

64

E

65

E

66

E

67

E

68

E

69

E70 E 80

Description of error

Condensation has formed.

This appears when the servo has been disengaged for 3 seconds during normal playback.

This appears when dropouts have been detected for two or more seconds during normal playback.

The reel base which operates in accordance with the size of the tape has been locked for more than 2.5 seconds.

The cassette has not moved down even when 4 seconds have elapsed since it was inserted. Alternatively, the cassette is not ejected even when 4 seconds have elapsed since the EJECT button was pressed.

The loading operation was not completed within 4 seconds.

The unloading operation was not completed within 4 seconds.

The FG (rotational speed) signal has not been output from the cylinder motor.

The PG (phase) signal has not been output from the cylinder motor.

The rotational speed of the cylinder motor is abnormally high.

The rotational speed of the cylinder motor is abnormally low.

The FG (rotational speed) signal has not been output from the capstan motor.

The rotational speed of the capstan motor is abnormally high.

The rotational speed of the capstan motor is abnormally low.

The supply reel motor has locked up.

The take-up reel motor has locked up.

The rotational speed of the supply reel motor is abnormally high.

The rotational speed of the take-up reel motor is abnormally high.

A tension error has been detected.

The start or end processing operation has not been completed even though 7 or more seconds have passed.

Communication error between SERVO and AVSYS. There is an error in the data.

Communication error between SERVO and AVSYS. The data has been fixed at high or low.

An error occurred in communication between SERVO and AVSYS when the power was turned on.

The fan motor stopped operating.

Trouble has occurred in the supply voltage.

36

Page 36
Image 36
Panasonic AJ-D230HP operating instructions Error No, Description of error