RS-232C Interface

Counter sense command

Send

Description of operation

Data transmitted by

command

personal computer

This command inquires as to the current value of the

QCD

[STX] QCD [ETX]

(COUNTER

counter. The CTL counter value or TCR value is returned.

 

SENSE)

The counter keys on the front panel or the menu is used to

 

 

select the CTL counter and TCR values.

 

Data received in

response from VTR

[STX] CDFS

[ETX]

Counter value

Counter value

For a CTL counter value Sign Hours Minutes Seconds Frames

–: –sign (2DH)

+: Blank (20H) For a TCR value

Hours Minutes Seconds Frames

Standby OFF commands

Send command

OBF (STANDBY OFF)

OBN (STANDBY

ON)

Description of operation

This command sets the VTR to the standby OFF mode. It is received when the VTR is in the stop mode.

This command sets the VTR to the standby ON mode. This operation is recognized when the VTR is in the standby OFF mode.

Data transmitted by

Data received in

personal computer

response from VTR

[STX] OBF [ETX]

[STX] OBF [ETX]

[STX] OBN [ETX]

[STX] OBN [ETX]

Deck ID command

Send

Description of operation

command

This command inquires as to the TV system

QID

(DECK IN

accommodated by the VTR.

SENSE)

 

Data transmitted by

Data received in

personal computer

response from VTR

[STX] QID [ETX]

[STX]

 

[ETX]

 

AJ-D230 : NTSC system

 

AJ-D230E : PAL system