Loosen the Ff ring clamping screw.
Set the zoom ring to the telephoto position manually or by electric drive.
Shoot the flange back adjustment chart and turn the distance ring to bring the chart into focus. Set the zoom ring to the wide-angle position.
Set the lens iris to manual.

Adjusting the Lens Flange

When images are not clearly focused at both the telephoto and wide-angle positions during zoom operations, adjust the flange back (the distance from the lens mounting surface to the image formation surface).

Once adjusted, the flange back does not need to be readjusted as long as the lens is not changed.

Adjustment method

Check the position of each part of the lens which must be operated in order to adjust the flange back with the lens Handling Instructions.

Approx. 10ft (3 m)

Adjusting the Flange Back

1

2 Open the iris. Position the flange back adjustment chart about 10ft (3 m) from the lens and illuminate it so that an appropriate image output level is obtained.

Use the filter and/or shutter if the video level is too high.

3

4

5

6

7 Turn the Ff ring to bring the chart into focus.

At this time, take care not to move the distance ring.

8 Repeat this operation four to seven times until the lens is in focus at both the telephoto and wide-angle positions.

9 Firmly tighten the Ff ring clamping screw.

ÁRefer to the Operating Instructions of the lens.

– 31 –

Page 31
Image 31
Panasonic AJ-D910WBP operating instructions Adjusting the Lens Flange, Adjustment method, Adjusting the Flange Back