Basic operations

ENGLISH

When the power is on

When the POWER button is pressed, the lamp for the PANEL ACTIVE button is on, and the settings of the camera recorder are read into the unit.

The respective numerical values are displayed on the PRE/A/B display, CC/ND display, GAIN display, and the IRIS display, while R GAIN and B GAIN are displayed on the LCD panel.

In this case, only the PANEL ACTIVE button, the SW ACTIVE button, the VR ACTIVE button, the AUTO IRIS button, M.PED volume and the IRIS volume can be operated from the unit, while other buttons and volumes are not operative. However, the settings on the A.KNEE ON button, the SHT ON button ,the AUTO IRIS button, the BAR ON/OFF button and the CHARA ON button will be in the states that had been set on the unit at the last time.

3)To display numerical values on the LCD panel

The GAIN volume is displayed when the power is on.

If the button operations are enabled, it is

possible to switch the displayed GAIN volume

# BLACK volume # a numerical value for M/ PED # TC step-by-step by using the 3button and the 4button.

When volume operation is enabled, the volume level is forcibly displayed if the GAIN volume or the BLACK volume is operated. However, it is possible to return the screen to the state before operating the GAIN volume or the BLACK volume by pressing the Rotary Encoder 3.

<Note>

It is impossible to switch the display when the unit menu or the camera menu is operating. The volume level is not displayed even if the volume is operated.

To enable the buttons/volumes

When the SW ACTIVE button is pressed and the lamp is on, button operations are enabled.

1)Operations of the camera part

When the SW ACTIVE button is pressed, operations of the USER MAIN button, GAIN and the camera recorder such as storing scene files in the built-in memory or reading them out, are enabled.

When the SW ACTIVE button is pressed again, the lamp is tuned off and button operations are inhibited, while the state of settings that have already been set previously is remained as it is.

2)Operation of the recording part

When the lamp of the RECORDER ENABLE button is turned off, operations of the recording part are disabled. Turn on the lamp of the RECORDER ENABLE button by pressing the button, and then operate the buttons of “PLAY”, “FF” or “REW”.

To record signals, operate the REC S/S button.

To disable buttons/volumes

If the lamp of the PANEL ACTIVE button is turned off, operations using the buttons and the volume on the panel are inhibited.

If the lamp of the VR ACTIVE button is turned off by pressing the button, setting the GAIN and BLACK using the volume controls is inhibited. Use this feature if you intend to retain the settings. However, note that if the volume is moved when inhibited, the volume level change will be reflected immediately after turning on the lamp of the PANEL ACTIVE button and/or the VR ACTICE button by pressing the button again.

<Note>

It is possible for the GAIN and the BLACK to avoid changes in the volume position during the inhibition by setting the volume mode on the unit menu to a relative value (REL).

E-16