Menu item (Continued)
FLAREWHITE

Layer

Item

Variable

Contents description

Storage

 

 

range

 

 

1

RFLAR

–100

To set the flare for Rch

Yes

 

 

:

 

 

 

+100

 

 

 

 

 

 

 

 

GFLAR

–100

To set the flare for Gch

Yes

 

 

:

 

 

 

+100

 

 

 

 

 

 

 

 

BFLAR

–100

To set the flare for Bch

Yes

 

 

:

 

 

 

+100

 

 

 

 

 

 

 

2

FLAR-

ON

To set ON/OFF of the

Yes

 

CORRECT

OFF

flare correction

 

 

 

 

 

 

 

<Note>

When the BLACK volume is assigned for flare adjustment, it must be set in BLACK-VR-CONTROL, BLACK-VR-MODE, and BLACK-VR-RANGE. When “FLR” is selected in the BLACK-VR-CONTROL item, the flare can be adjusted by using the BLACK volume. Switching between the absolute value mode and the relative value mode of the volume can be set in the BLACK-VR-MODE item, while switching of the variable range can be set in the BLACK-VR-RANGE item. When the absolute value is selected in the BLACK-VR-MODE item or the lamp of the VR-ACTIVE button is turned on, R FLAR/G FLAR/B FLAR items cannot be adjusted using the rotary encoder. They must be adjusted with the BLACK volume.

GAMMA

Layer

Item

Variable

Contents description

Storage

 

 

range

 

 

1

RGAM

–15

To set the gamma for

Yes

 

 

:

Rch

 

 

+15

 

 

 

 

 

 

 

 

MGAM

0.30

To set the master

Yes

 

 

:

gamma

 

 

0.75

 

 

 

 

 

 

 

 

BGAM

–15

To set the gamma for

Yes

 

 

:

Bch

 

 

+15

 

 

 

 

 

 

 

2

GAMMA-

HD

To select the gamma

 

 

MODE-SEL

SD

 

Yes

 

 

F-LIKE1

 

 

 

F-LIKE2

 

 

 

 

F-LIKE3

 

 

 

 

 

 

 

3

GAMMA-

ON

To set ON/OFF of the

Yes

 

CORRECT

OFF

gamma correction

 

 

 

 

 

 

 

Layer

Item

Variable

Contents description

Storage

 

 

range

 

 

 

1

RGAIN

–200

To set the Rch gain

Yes

 

 

:

 

 

 

 

+200

 

 

 

 

 

 

 

 

 

BGAIN

–200

To set the Bch gain

Yes

 

 

:

 

 

 

 

+200

 

 

 

 

 

 

 

 

2

FILTER-INH

ON

To select whether the

 

 

 

OFF

filter has data for the

 

 

 

 

AWB memory (Ach,

 

 

 

 

Bch) or not, for the

 

 

 

 

respective filters

 

 

 

 

independently

Yes

 

 

 

ON:

Data are held in

 

 

 

 

two memory

 

 

 

 

 

locations (Ach,

 

 

 

 

 

Bch) regardless

 

 

 

 

 

of the filter.

 

 

 

 

OFF: The respective

 

 

 

 

 

filters hold data.

 

 

 

 

 

 

3

SKLS-AWB

OFF

To turn on the shock-

 

 

 

FAST

less AWB (FAST/

 

 

 

NORMAL

NORMAL/SLOW1/

Yes

 

 

SLOW1

SLOW2/SLOW3)

 

 

 

 

 

SLOW2

 

 

 

 

 

SLOW3

 

 

 

 

 

 

 

 

 

AWBAREA

25%

To switch the AWB

Yes

 

 

50%

detection area

 

 

90%

 

 

 

 

 

 

 

 

4

GAIN-VR-

ABS

To select whether the

 

 

MODE

REL

GAIN volumes for R

 

 

 

 

and B are operated

 

 

 

 

using the absolute

Yes

 

 

 

value or the relative

 

 

 

 

 

 

 

value

 

 

 

 

 

ABS: Absolute value

 

 

 

 

REL: Relative value

 

 

 

 

 

 

5

GAIN-VR-

MIN

To switch the variable

 

 

RANGE

NORM

range of the GAIN

 

 

 

MAX

volumes for R and B

Yes

 

 

 

MIN:

n50

 

 

 

 

 

 

 

NORM: n100

 

 

 

 

MAX:

n200

 

<Note>

When the absolute value is selected in the GAIN-VR- MODE item, or the lamp of the VR ACTIVE button is turned on, the R GAIN/G GAIN items cannot be adjusted using the rotary encoder. They must be adjusted using the GAIN volume.

is the factory setting mode.

E-25