Connector signals

Pin no.

Signal

Direction

Type

Description

 

 

 

 

 

 

 

29

FF STATUS

OUTPUT

ACTIVE_L

This becomes active when the VTR is in the FF mode.

 

 

 

 

 

30

REW STATUS

OUTPUT

ACTIVE_L

This becomes active when the VTR is in the REW mode.

 

 

 

 

 

31

STOP STATUS

OUTPUT

ACTIVE_L

This becomes active when the VTR is in the STOP mode.

 

 

 

 

 

32

RE-422 REMOTE

OUTPUT

ACTIVE_L

This becomes active when the RS-422 REMOTE status is

 

ON STATUS

 

 

ON.

 

 

 

 

 

 

 

33

EJECT STATUS

OUTPUT

ACTIVE_L

This becomes active when a cassette tape has not been

 

 

 

 

inserted.

 

 

 

 

 

 

 

34

ERR 2 STATUS

OUTPUT

ACTIVE_L

Refer to the 50P error status output table on the previous

 

 

 

 

page. (This pin is related with pins 21 and 24.)

 

 

 

 

 

 

 

35

TC SOURCE

OUTPUT

ACTIVE_L (1)

11: INT

10: EXT_LTC

 

36

STATUS

 

Open (0)

01: S_VITC (EXT VITC) 00: S_LTC

[Pin 36, pin 35]

 

 

 

 

 

 

37

TC SLAVE

OUTPUT

ACTIVE_L (1)

[Pin 38, pin 37] TC SOURCE

 

 

STATUS

 

Open (0)

At INT setting

At EXT setting

Other

 

 

 

 

11: PRESET

SLAVE

–––––

38

 

 

 

 

 

 

10: AUTO

DIRECT

–––––

 

 

 

 

01: –––––

–––––

–––––

 

 

 

 

00: SLAVE

–––––

–––––

 

 

 

 

 

 

 

39

REC INH MENU

OUTPUT

ACTIVE_L (1)

[Pin 40, pin 39]

 

 

 

STATUS

 

Open (0)

11: FREE

10: ALL

 

40

 

 

 

 

 

01: NRML, REC

 

 

 

 

 

 

 

41

CUE STATUS

OUTPUT

ACTIVE_L

This becomes active when the preroll or cue-up operation

 

 

 

 

has been completed. However, the active status is

 

 

 

 

released when the VTR has moved from the STBY ON or

 

 

 

 

OFF operation to another operation.

 

 

 

 

 

 

42

REMOTE STATUS

OUTPUT

ACTIVE_L

This becomes active when 50P parallel control is enabled.

 

 

 

 

 

43

CASSETTE INH

OUTPUT

ACTIVE_L

This becomes active when the VIDEO/CTL recording

 

1 STATUS

 

 

setting for CASSETTE INH has been set to inhibit.

 

 

 

 

(However, the active status is forcibly released when

 

 

 

 

CASSETTE INH 2 [pin 45] is set to ACTIVE.)

 

 

 

 

 

44

PRE CTL

OUTPUT

ACTIVE_L

This becomes active when CTL has been detected at the

 

DETECT

 

 

PRE CTL head during normal recording at the PRE CTL

 

 

 

 

setting.

 

 

 

 

 

 

Note: This will not become active even if CTL has been

 

 

 

 

detected during recording (EDIT REC) or PLAY

 

 

 

 

while editing is being performed.

 

 

 

 

 

In the same way, it will not become active even if

 

 

 

 

CTL has been detected during normal recording

 

 

 

 

when the home menu function (REC INH) setting

 

 

 

 

has been set to FREE.

 

 

 

 

 

 

45

CASSETTE INH

OUTPUT

ACTIVE_L

This becomes active when CASSETTE INH has been set

 

2 STATUS

 

 

to the all recording inhibit status.

 

 

 

 

 

 

46

STBY STATUS

OUTPUT

ACTIVE_L

This becomes active when the VTR has been placed in

 

 

 

 

the STBY ON status.

 

 

 

 

 

 

The ACTIVE lamp flashes (at 2-second intervals) starting

 

 

 

 

30 seconds before the VTR is transferred to the loosing mode.

 

 

 

 

It flashes (at 0.5-second intervals) starting 10 seconds

 

 

 

 

before the VTR is transferred to the STBY OFF mode.

 

 

 

 

 

 

 

47

GND

OUTPUT

 

GND

 

 

 

 

 

 

 

48

LOCAL STATUS

OUTPUT

ACTIVE_L

This becomes active when the REMOTE OP MAP

 

 

 

 

functions are enabled.

 

 

 

 

 

 

 

 

 

49

GND

OUTPUT

 

GND

 

 

 

 

 

 

 

 

 

50

GND

OUTPUT

 

GND

 

 

 

 

 

 

 

 

 

– 47 –

Page 47
Image 47
Panasonic AJ- HD3700B manual FF Status Output Activel