Chapter 7 Menu description tables (continued)

7-3-6 MID SETTING

 

Item

Variable

 

 

Remarks

 

 

range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER GAIN

–3dB

For setting the master gain to –3, 0, 3, 6, 9,

 

 

 

 

 

:

12, 15, 18, 21, 24, 27 or 30 dB.

 

 

 

 

 

 

6dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

30dB

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.DTL LEVEL

00

For

performing

the

horizontal

detail

 

 

 

 

 

:

correction level setting.

 

 

 

 

 

 

 

08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

63

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.DTL LEVEL

00

For performing the vertical detail correction

 

 

 

 

 

:

level setting.

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

DTL CORING

00

For performing the noise elimination level

 

 

 

 

 

:

setting for detail.

 

 

 

 

 

 

 

 

02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.DTL FREQ.

00

For

performing

the

horizontal

detail

 

 

 

 

 

:

frequency selection.

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

LEVEL DEPEND.

0

For setting the LEVEL DEPEND.

 

 

 

 

 

 

1

When the Y-detail is emphasized, details of

 

 

 

 

 

:

dark sections are compressed.

 

 

 

 

 

 

5

 

 

 

 

 

 

If the numerical value is larger, details of

 

 

 

 

 

 

 

 

 

 

 

 

bright sections are also compressed.

 

S

C

U

F

R

 

 

 

 

 

 

MASTER GAMMA

0.30

For setting the master gamma.

 

 

 

 

 

 

:

(0.01 step)

 

 

 

 

 

 

 

 

0.45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

0.75

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK GAMMA

–3

For setting the gamma curve for the dark

 

 

 

 

 

:

portion.

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

–3 to –1:

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

+3

The dark portion is compressed.

 

 

 

 

 

 

 

OFF:

 

 

 

 

 

 

 

 

 

 

Standard state

 

 

 

 

 

 

 

 

 

+1 to +3:

 

 

 

 

 

 

 

 

 

The dark portion is extended.

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MATRIX TABLE

OFF

For selecting the color correction table for

Athe linear matrix.

S C U F R B

COLOR

ON

For switching ON/OFF of the 12-axis

CORRECT

OFF

independent color correction.

S U F R

<Note>

Items with $ in front of their names are set by the PAINT MENU SW ($) R/W menu items on the <CARD R/W SELECT> screen.

Items without $ in front of their names are set by the PAINT MENU LEVEL R/W menu item.

For details, refer to “7-6-2 CARD R/W SELECT.”

7-3-7 HIGH SETTING

 

Item

Variable

 

 

Remarks

 

 

range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER GAIN

–3dB

For setting the master gain to –3, 0, 3, 6, 9,

 

 

 

 

 

:

12, 15, 18, 21, 24, 27 or 30 dB.

 

 

 

 

 

 

12dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

30dB

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.DTL LEVEL

00

For

performing

the

horizontal

detail

 

 

 

 

 

:

correction level setting.

 

 

 

 

 

 

 

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

63

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.DTL LEVEL

00

For performing the vertical detail correction

 

 

 

 

 

:

level setting.

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

DTL CORING

00

For performing the noise elimination level

 

 

 

 

 

:

setting for detail.

 

 

 

 

 

 

 

 

03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.DTL FREQ.

00

For

performing

the

horizontal

detail

 

 

 

 

 

:

frequency selection.

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

S

C

U

F

R

 

 

 

 

 

 

LEVEL DEPEND.

0

For setting the LEVEL DEPEND.

 

 

 

 

 

 

:

When the Y-detail is emphasized, details of

 

 

 

 

 

3

 

 

 

 

 

dark sections are compressed.

 

 

 

 

 

 

:

 

5If the numerical value is larger, details of bright sections are also compressed.

S C U F R

MASTER GAMMA

0.30

For setting the master gamma.

 

 

 

 

 

:

(0.01 step)

 

 

 

 

 

0.55

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

0.75

 

S

C

U

F

R

 

 

 

 

 

 

 

 

 

BLACK GAMMA

–3

For setting the gamma curve for the dark

 

 

 

 

 

:

portion.

 

 

 

 

 

OFF

 

 

 

 

 

–3 to –1:

 

 

 

 

 

:

 

 

 

 

 

+3

The dark portion is compressed.

 

 

 

 

 

 

OFF:

 

 

 

 

 

 

Standard state

 

 

 

 

 

 

+1 to +3:

 

 

 

 

 

 

The dark portion is extended.

S

C

U

F

R

 

 

 

 

 

 

 

 

 

MATRIX TABLE

OFF

For selecting the color correction table for

Athe linear matrix.

S C U F R B

COLOR

ON

For switching ON/OFF of the 12-axis

CORRECT

OFF

independent color correction.

S U F R

The underlining in the variable range column indicates the setting in the preset mode.