Chapter 6 Maintenance and inspections (continued)
REMOTE
1 | CAM DATA (H) | Data from the camera to the remote control (H) |
|
|
|
2 | CAM DATA (C) | Data from the camera to the remote control (C) |
|
|
|
3 | CAM CONT (H) | Control signals from the remote control to the camera (H) |
|
|
|
4 | CAM CONT (C) | Control signals from the remote control to the camera (C) |
|
|
|
5 | Identification signals of the remote control | |
|
| Low: ON |
|
|
|
6 | RC VIDEO OUT | Video signals output to the remote control |
|
|
|
7 | RC VIDEO GND | GND of the video signals to the remote control |
|
|
|
8 | NC | Not used |
|
|
|
9 | UNREG 12V | DC +12 V power supply |
|
|
|
10 | GND | GND |
|
|
|
Matsushita part number K1AY110JA001
Maker part number
Connector at the cable side
Maker part number | |
| (Hirose Denki) |
81
7 10 9 2
63
5 4
6
VF
1 | DC +12 V power supply | |
|
|
|
2 | DC +12 V power supply | |
|
|
|
3 | A9.0V | DC +9 V power supply (not used) |
|
|
|
4 | GND for the viewfinder PB signals | |
|
|
|
5 | GND for the viewfinder PR signals | |
|
|
|
6 | Viewfinder Y signals output | |
|
|
|
7 | GND for the viewfinder Y signals | |
|
|
|
8 | Serial data clock pulse signals | |
|
|
|
9 | Pulse signals for reading | |
|
| data |
|
|
|
10 | Serial data signals for | |
|
|
|
11 | GND | |
|
|
|
12 | ON/OFF of the zebra signals | |
|
|
|
13 | PEAKING | Control of the peaking (not used) |
|
|
|
14 | SPARE | Standby (not used) |
|
|
|
15 | Viewfinder PR signal output | |
|
|
|
16 | Viewfinder PB signal output | |
|
|
|
17 | ON/OFF of the marker (not used) | |
|
|
|
18 | FRONT AUDIO LEVEL adjustment (not used) | |
|
|
|
19 | GND for the FRONT AUDIO LEVEL (not used) | |
|
|
|
20 | GND | |
|
|
|
Caution:
Total amount of current from the respective connectors for DC OUT, REMOTE, VF, and LENS should not exceed 2.5 A.
Matsushita part number K1AB120H0001
Maker part number
1 2 3 4 5
6 7 8 9 10
11 12 13 14 15
16 17 18 19 20
95