Chapter 6 Maintenance and inspections (continued)

REMOTE

1

CAM DATA (H)

Data from the camera to the remote control (H)

 

 

 

2

CAM DATA (C)

Data from the camera to the remote control (C)

 

 

 

3

CAM CONT (H)

Control signals from the remote control to the camera (H)

 

 

 

4

CAM CONT (C)

Control signals from the remote control to the camera (C)

 

 

 

5

RC-ON

Identification signals of the remote control

 

 

Low: ON

 

 

 

6

RC VIDEO OUT

Video signals output to the remote control

 

 

 

7

RC VIDEO GND

GND of the video signals to the remote control

 

 

 

8

NC

Not used

 

 

 

9

UNREG 12V

DC +12 V power supply (AJ-RC10G: Max. 0.75 A)

 

 

 

10

GND

GND

 

 

 

Matsushita part number K1AY110JA001

Maker part number HR10A-10R-10SC (71) (Hirose Denki)

Connector at the cable side

Maker part number

HR10A-10P-10P(73)

 

(Hirose Denki)

81

7 10 9 2

63

5 4

6

VF

1

UNREG-12V

DC +12 V power supply (AJ-HVF21G: About 0.35 A)

 

 

 

2

UNREG-12V

DC +12 V power supply

 

 

 

3

A9.0V

DC +9 V power supply (not used)

 

 

 

4

VF-PB-GND

GND for the viewfinder PB signals

 

 

 

5

VF-PR-GND

GND for the viewfinder PR signals

 

 

 

6

VF-Y

Viewfinder Y signals output

 

 

 

7

VF-Y-GND

GND for the viewfinder Y signals

 

 

 

8

VF-CLK

Serial data clock pulse signals

 

 

 

9

VF-WR

Pulse signals for reading serial-parallel conversion

 

 

data

 

 

 

10

VF-DATA

Serial data signals for serial-parallel conversion

 

 

 

11

UNREG-GND

GND

 

 

 

12

ZEBRA-SW

ON/OFF of the zebra signals

 

 

 

13

PEAKING

Control of the peaking (not used)

 

 

 

14

SPARE

Standby (not used)

 

 

 

15

VF-PR

Viewfinder PR signal output

 

 

 

16

VF-PB

Viewfinder PB signal output

 

 

 

17

MARKER-SW

ON/OFF of the marker (not used)

 

 

 

18

FRONT-VR

FRONT AUDIO LEVEL adjustment (not used)

 

 

 

19

VR-GND

GND for the FRONT AUDIO LEVEL (not used)

 

 

 

20

UNREG-GND

GND

 

 

 

Caution:

Total amount of current from the respective connectors for DC OUT, REMOTE, VF, and LENS should not exceed 2.5 A.

Matsushita part number K1AB120H0001

Maker part number HR12-14RA-20SC (Hirose Denki)

1 2 3 4 5

6 7 8 9 10

11 12 13 14 15

16 17 18 19 20

95