Chapter 4 Adjustments and settings for recording (continued)

4-10-5 Method for returning to user settings

It is possible to return the settings of the menu on the unit to the user settings that were registered previously in accordance with “4-10-3 How to use the user data.”

There are two methods: one that reads out the USER DATA saved in accordance with “4-10-3 How to use the user data,” and the other method that returns without menu operations.

Operation method without performing FILE menu operations

1 Set the POWER switch to the OFF position.

2 Set the WHITE BAL switch to the PRST position.

WHITE BAL switch

4-10-6 Method for returning to the factory settings

It is possible to return the settings of the menu on the unit to the factory settings.

1

Open the <INITIALIZE> screen with the menu

 

 

operations.

 

2

Move the arrow (cursor) to the READ FACTORY DATA

4

 

by turning the JOG dial button.

<INITIALIZE >

#READ FACTORY DATA WRITE USER DATA

3 Press the JOG dial button to display the following message.

3 Set the POWER switch to the ON position while holding up the AUTO W/B BAL switch.

The USER menu item settings are all returned together to the standard user data.

READ?

YES

# NO

4 Move the arrow (cursor) to YES by turning the JOG dial button, and then press the JOG dial button.

The unit is reset to the factory settings. O User data is not changed.

5 Press the MENU button to exit the menu operations.

73